P333
Internal Resistance – The resistance measured across the sensing element when a specified DC voltage is applied at room conditions unless otherwise stated.
Add comment
P334
Load Impedance 1 – The impedance presented to the output terminals of a transducer by the associated external circuitry.
Add comment
P335
Output Impedance: 1 – The impedance across the output terminals of a transducer by the associated external circuitry.
Add comment
P336
Parasitic Capacitance – The portion of the quiescent capacitance that is due to the capacitance of aspects of the transducer circuit other than the transducer element. This capacitance does not change due to changes in the measurand, but may change do to other inputs such as temperature changes, vibration, etc.
Add comment
P338
Quiescent Capacitance – The capacitance of a sensing element plus associated capacitance of electrical connections between the transducer element and the first stage of signal conditioning electronics when no or default measurand is applied.
Add comment
P342
Shunting Resistance – The resistance between two not internally connected output terminals of a transducer.
Add comment
P343
Transducer Capacitance – The total capacitance of the sensing element, sensor package and integrated cabling.
Add comment
P344
Cable Robustness – Properties of the cable that specify what applications the cable can endure without being damaged. E.g. temperature capability, tensile strength, bending radius ...
Add comment
P345
Dead Volume 1 – The total volume of the pressure port cavity of a transducer with room barometric pressure applied.
Add comment
P346
Mounting Error 1 – The error resulting from mechanical deformation of the transducer caused by mounting the transducer and making all measurand and electrical connections.
Add comment
P347
Mounting Force for Non-Threaded Transducers – The minimum to the maximum specified force used when a non-threaded transducer is tightened into the mounting port, specified in units of N or equivalent.
Add comment
P349
Mounting Torque – The minimum to the maximum specified torque used when a threaded transducer is tightened into the mounting port, specified in units of Nm or equivalent.
Add comment
P350
Strain Sensitivity – Denoted as “Mechanical Isolation of Transduction Element” in ISA RP37.2-1964. Internal construction of a transducer, which allows forces (particularly bending forces and external pressures) to be applied to the transducer case with negligible resulting forces on the transducer element. Quantification technique described in Section 6.6 of ISA RP37.2-1964 for capacitive transducers.
Add comment
P351
Zero Change with Torque – The change in the zero-measurand output of a transducer without torque applied to the specified transducer mounting torque when the specified sealing mechanism (e.g. crush ring, o-ring) is employed. Specified in terms of +/- __ % FSO/(N*m) for a specified sealing mechanism (unless otherwise specified).