P238
Zero-Measurand Output 1 – The output of a transducer, under room conditions, unless otherwise specified, with nominal excitation zero measurand applied.
Add comment
P239
Zero Shift – A change in the zero-measurand output over time at room conditions. NOTE: This error is characterized by a parallel displacement of the entire calibration curve.
Add comment
Pressure
P240
Burst pressure rating 1 – The pressure which may be applied to the sensing element or the case (as specified) of a transducer without rupture of either the sensing element or transducer case as specified.
Add comment
P241
NOTE: Minimum number of applications and time duration of each application must be specified,
Add comment
P242
NOTE: In the case of transducers intended to measure a property of a pressurized fluid, burst pressure is applied to the portion subjected to the fluid.
Add comment
P243
Capacitive Response to Pressure (CRP) – The relationship between pressure and the change in capacitance of the pressure transducer. NOTE: Applicable for capacitive transducers.
Add comment
P244
Dynamic Range – The ratio of specified maximum measurand value to the threshold value. It may also be measured as a base-10 (decibels) logarithmic value in dB, or base-2 logarithmic value (in bits).
Add/View comment (1)

P246
Overload 1 – The maximum magnitude of measurand that can be applied to a transducer without causing a change in performance beyond specified tolerance.
Add comment
P247
Peak Pressure – The highest observed pressure peak at the measurement point within a system.
Add comment
P248
Peak-to-Peak Pressure (Double Amplitude) – The difference in pressure from the peak to the trough of a sinusoidal dynamic pressure.
Add comment
P250
Proof Pressure 1 – The maximum pressure which may be applied to the sensing element of a transducer without changing the transducer performance beyond specified tolerances.
Add comment
P251
Sensitivity Stability at a Specified Static Pressure – The variation in sensitivity at a specified static pressure and at a specified constant temperature over a specified period of time. Specified as ± __ % full scale output (with necessary signal conditioning when applicable) per hour.
Add comment
Temperature
P252
Back-End Operating Temperature Rating – The operating temperature capability of the back of transducer and connector, if applicable.
Add comment
P253
Capacitive Response to Temperature (CRT) – The relationship between temperature and capacitance change of the pressure transducer. Temperature response may be compensated for by signal conditioning electronics, and possibly with the addition of a temperature transducer integrated into the pressure sensor system.
Add comment
P255
Connector Operating Temperature Range – The operating temperature range capability of the connector and mating connector.