It can take a while depending on the size of the document..please wait
Discuto
0 days left (ends 14 May)
description
This discussion is open for a limited time. Please review, comment and vote for the individual sections. You can quote certain parts of a paragraph by marking the text and open a comment.
Further info
LATEST ACTIVITY
LEVEL OF AGREEMENT
MOST DISCUSSED PARAGRAPHS
LATEST COMMENTS
MOST ACTIVE USERS
                
                    
                        P238                    
                                  
            
                Zero-Measurand Output 1 – The output of a transducer, under room conditions, unless otherwise specified, with nominal excitation zero measurand applied.
Add comment
                
                    
                        P239                    
                                  
            
                Zero Shift – A change in the zero-measurand output over time at room conditions. NOTE: This error is characterized by a parallel displacement of the entire calibration curve.
Add comment
Pressure
                
                    
                        P240                    
                                  
            
                Burst pressure rating 1 – The pressure which may be applied to the sensing element or the case (as specified) of a transducer without rupture of either the sensing element or transducer case as specified.
Add comment
                
                    
                        P241                    
                                  
            
                NOTE: Minimum number of applications and time duration of each application must be specified,
Add comment
                
                    
                        P242                    
                                  
            
                NOTE: In the case of transducers intended to measure a property of a pressurized fluid, burst pressure is applied to the portion subjected to the fluid.
Add comment
                
                    
                        P243                    
                                  
            
                Capacitive Response to Pressure (CRP) – The relationship between pressure and the change in capacitance of the pressure transducer. NOTE: Applicable for capacitive transducers.
Add comment
                
                    
                        P244                    
                                  
            
                Dynamic Range – The ratio of specified maximum measurand value to the threshold value. It may also be measured as a base-10 (decibels) logarithmic value in dB, or base-2 logarithmic value (in bits).
Add/View comment (1)

                
                    
                        P246                    
                                  
            
                Overload 1 – The maximum magnitude of measurand that can be applied to a transducer without causing a change in performance beyond specified tolerance.
Add comment
                
                    
                        P247                    
                                  
            
                Peak Pressure – The highest observed pressure peak at the measurement point within a system.
Add comment
                
                    
                        P248                    
                                  
            
                Peak-to-Peak Pressure (Double Amplitude) – The difference in pressure from the peak to the trough of a sinusoidal dynamic pressure.
Add comment
                
                    
                        P250                    
                                  
            
                Proof Pressure 1 – The maximum pressure which may be applied to the sensing element of a transducer without changing the transducer performance beyond specified tolerances.
Add comment
                
                    
                        P251                    
                                  
            
                Sensitivity Stability at a Specified Static Pressure – The variation in sensitivity at a specified static pressure and at a specified constant temperature over a specified period of time. Specified as ± __ % full scale output (with necessary signal conditioning when applicable) per hour.
Add comment
Temperature
                
                    
                        P252                    
                                  
            
                Back-End Operating Temperature Rating – The operating temperature capability of the back of transducer and connector, if applicable.
Add comment
                
                    
                        P253                    
                                  
            
                Capacitive Response to Temperature (CRT) – The relationship between temperature and capacitance change of the pressure transducer. Temperature response may be compensated for by signal conditioning electronics, and possibly with the addition of a temperature transducer integrated into the pressure sensor system.
Add comment
                
                    
                        P255                    
                                  
            
                Connector Operating Temperature Range – The operating temperature range capability of the connector and mating connector.
 
			 
					 
                       
                       
                      
 
								 
						   
  
Did you know you can vote on comments? You can also reply directly to people's comments.