Discuto is Loading your document from Drive

It can take a while depending on the size of the document..please wait

Discuto is submitting your document

It might take a while depending on the size of the document you uploaded..

Discuto is creating your discussion

Please do not close this window.

Discuto is submitting your comment

Did you know you can vote on comments? You can also reply directly to people's comments.

Your invites are being queued for sending

This might take some time depending on the number of invites, please do not close this window.

Discuto

Discuto

Whitepaper Draft V0_1_1

Starting: 14 Apr Ending

0 days left (ends 14 May)

Go to discussion, participate and give your opinion

description

This discussion is open for a limited time. Please review, comment and vote for the individual sections. You can quote certain parts of a paragraph by marking the text and open a comment.

Further info

LATEST ACTIVITY

LATEST COMMENTS

Status: Closed
Privacy: Public

CONTRIBUTORS (8)

Share:
_
<< Previous paragraphs

P238

Zero-Measurand Output 1 – The output of a transducer, under room conditions, unless otherwise specified, with nominal excitation zero measurand applied.

You agreeCan't vote

Add comment

P239

Zero Shift – A change in the zero-measurand output over time at room conditions. NOTE: This error is characterized by a parallel displacement of the entire calibration curve.

You agreeCan't vote

Add comment

Pressure

P240

Burst pressure rating 1 – The pressure which may be applied to the sensing element or the case (as specified) of a transducer without rupture of either the sensing element or transducer case as specified.

You agreeCan't vote

Add comment

P241

NOTE: Minimum number of applications and time duration of each application must be specified,

You agreeCan't vote

Add comment

P242

NOTE: In the case of transducers intended to measure a property of a pressurized fluid, burst pressure is applied to the portion subjected to the fluid.

You agreeCan't vote

Add comment

P243

Capacitive Response to Pressure (CRP) – The relationship between pressure and the change in capacitance of the pressure transducer. NOTE: Applicable for capacitive transducers.

You agreeCan't vote

Add comment

P244

Dynamic Range – The ratio of specified maximum measurand value to the threshold value. It may also be measured as a base-10 (decibels) logarithmic value in dB, or base-2 logarithmic value (in bits).

You agreeCan't vote

Add/View comment (1)

people_img

P245

Overrange – See overload

You agreeCan't vote

Add comment

P246

Overload 1 – The maximum magnitude of measurand that can be applied to a transducer without causing a change in performance beyond specified tolerance.

You agreeCan't vote

Add comment

P247

Peak Pressure – The highest observed pressure peak at the measurement point within a system.

You agreeCan't vote

Add comment

P248

Peak-to-Peak Pressure (Double Amplitude) – The difference in pressure from the peak to the trough of a sinusoidal dynamic pressure.

You agreeCan't vote

Add comment

P249

Pressure Overload – See proof pressure

You agreeCan't vote

Add comment

P250

Proof Pressure 1 – The maximum pressure which may be applied to the sensing element of a transducer without changing the transducer performance beyond specified tolerances.

You agreeCan't vote

Add comment

P251

Sensitivity Stability at a Specified Static Pressure – The variation in sensitivity at a specified static pressure and at a specified constant temperature over a specified period of time. Specified as ± __ % full scale output (with necessary signal conditioning when applicable) per hour.

You agreeCan't vote

Add comment

Temperature

P252

Back-End Operating Temperature Rating – The operating temperature capability of the back of transducer and connector, if applicable.

You agreeCan't vote

Add comment

P253

Capacitive Response to Temperature (CRT) – The relationship between temperature and capacitance change of the pressure transducer. Temperature response may be compensated for by signal conditioning electronics, and possibly with the addition of a temperature transducer integrated into the pressure sensor system.

You agreeCan't vote

Add comment

P254

NOTE: Applicable to capacitive transducers.

You agreeCan't vote

Add comment

P255

Connector Operating Temperature Range – The operating temperature range capability of the connector and mating connector.

You agreeCan't vote

Add comment