Electromagnetic 1 – Converting a change of measurand into an output induced in a conductor by a change in magnetic flux, in the absence of excitation.
Add comment
P181
Inductive 1 – Converting a change of measurand into a change of self-inductance of a single coil.
Add comment
P182
Microwave – Converting a change of measurand into a change in intensity, phase, polarization, wavelength or transit time.
Add comment
P183
Optical – Converting a change of measurand into a change in light intensity, phase, polarization, wavelength or transit time.
Add comment
P184
Piezoelectric 1 – Converting a change of measurand into a change in the electrostatic charge or voltage generated by certain materials when mechanically stressed.
Add comment
P187
Strain-Gage 1 – Converting a change of measurand into a change or resistancedue to strain.
Add comment
P189
Combined Uncertainties at High Temperature – RSS of the uncertainties at high temperature
Add comment
P190
Combined Uncertainties at Room Temperature – RSS of the uncertainties at room temperature.
Add comment
P191
Creep 1 – A change in output occurring over a specific time period while the measurand and all environmental conditions are held constant.
Add comment
P192
Drift 1 – An undesired change in output over a period of time, which change is not a function of the measurand.
Add comment
P193
Electromagnetic Susceptability – The apparent susceptability of a sensor or sensor and signal conditioning to external electromagnetic energy. It is expressed as “unit of pressure per unit field strength at a specified frequency for a specific installation."
Add comment
P195
NOTE: Unless otherwise specified, end points are averaged during any one calibration.
Add comment
P196
Friction Error 1 – The maximum change in output, at any measurand value within the specified range, before and after minimizing friction within the transducer by dithering.